Excellent Series
Test the reliability of your products in different temperatures and humidity. The Constant Temperature & Humidity Chamber allows you to keep the desired temperature and humidity at all times without any effort, saving you time and energy. Constant temperature and humidity chambers simulate the real-world thermal conditions of a product in use. It is especially suited for testing of devices with electric or electronic components, and the materials that come into contact with them. The Excellent Series chambers can maintain temperatures from – 70°C to 150°C and relative humidities from 20% to 98% RH depending on the model.
Rapid Temperature Change
The heating/cooling between -40℃ to 85℃ under gradient control has achieveda temperature change rate of 10℃/min and 5℃/min.
Shortening of the evaluation test time
Depend on the fast temperature rise / drop time, shift time to the set temperature is largely shortened. (Compared to Standard / Low temperature series, 52 hours ⇒ 26 hours)
Improved temperature change rate performance.
Improved the performance of temperature change rate of material temperature control to 15℃/min (EC-25EX Series).
Addition of temperature cycle operation function.
“Temperature Cycle Operation Function” which are available to setup “High-temp soak”, “Low-temp soak”, “lamp control”, or “material temperature control” are added.
Addition of temperature cycle operation function
“Temperature Cycle Operation Function” which are available to
setup “High-temp soak” , “Low-temp soak” , “lamp control” , or
“material temperature control” are added.
Correspond to humidity control function
Line-up humidity control corresponding type. Temperature cycle test or temperature / humidity test can be corresponded by one unit.
※Humidity control operation:Effective when ” Power Saving mode” or “Standard mode” is set up.
Heat load allowance
Heat load allowance enables durability of high heat and no compromise of performance.
Digital over-heat prevention thermostat
Digital over-heat prevention thermostat was adopted as a replacement for the conventional dial over-heat prevention thermostat and
improved the setting operation and temperature control system.
Remote Control Operation
Operation from around the world with remote access interfacing. Allows connecting up to 15 chambers from one PC.
Energy saving performance
Inverter control of scroll compressor( 600W)performs great energy saving effect at all the area of temperature &
temperature/humidity control range.
Program name input function
At this function, you may input a program name. Program
name can be input by using alphabet, number, and symbols (!”#%&’()@:,.=+-*/?_) for 14 words (maximum).
Various types of communication interface
By using communication interface, unit is being enabled
to external control on operations and measurements from a connected computer or user’s original system unit.
Combined-program operate function
At this function, you may operate 2 or more programs continuously (or by combination). Up to 5 combined
programs can be operated at maximum.
High load correspondence
Correspond to heat load at high-temp/high-humid or low-temp condition.
Correspond to humidity control function
Line-up humidity control corresponding type. Temperature cycle test or temperature/ humidity test can be corresponded by one unit.
※Humidity control operation:Effective when ” Power Saving mode” or “Standard mode” is set up.
Operation mode changeable function
Standard equipped the “operation mode changeable function” which can change unit refrigerant ability by operation mode (“Energy Saving mode”,”Standard mode”,”High Load mode”).
Unit Control Panel
Color LCD Touch Panel
The color LCD touch panel is adopted so that setting and controlling of the unit will be simple only by touching the displays. The color LCD offers clear view and the system is supported for diverse functions in operation control.
Program name input function
At this function, you may input a program name. Program name can be input by using alphabet, number, and
symbols (!”#%&’()@:,.=+-*/?_) for 14 words (maximum).
Various types of communication interface
By using communication interface, unit is being enabled to external control on operations and measurements from a connected computer or user’s original system unit.
Combined-program operate function
At this function, you may operate 2 or more programs continuously (or by combination). Up to 5 combined programs can be operated at maximum.
Various types of communication interface
By using communication interface, unit is being enabled
to external control on operations and measurements from a connected computer or user’s original system unit.