Can be customized according to your requirement
Double Side Access Series
Test the reliability of your products in different temperatures. The Constant TemperaturenChamber allows you to keep the desired temperature and humidity at all times without any effort, saving you time and energy. Constant temperature chambers simulate the real-world thermal conditions of a product in use. It is especially suited for testing of devices with electric or electronic components, and the materials that come into contact with them. The Double Side Access Series chambers can maintain temperatures from – 40°C to 100°C depending on the model.
Specially Designed for Battery Testing
Chambers dedicated to battery testing.
Water Immersion Cooling
Water Immersion Cooling system enables quick removal of heat.
Inner Sprinkler System
Liquid Sprinkler System with manual switch and emergency stop.
Smoke Detector
Built in smoke detector that can detect any smoke emitted while testing.
Available to eject testing material cable from either side of chamber. Correspond to evaluation system for rechargeable battery.
(Secondary battery is also said as storage battery or rechargeable battery, which is a battery of charge / discharge use.)
Correspond continuous test
By controlling at evaporate temperatures, continuous tests (*) are available at low-temp/low-humid control region.
*(excluding maintenance time such as wick exchange)
Correspond heat load
Corresponding to 500W sensible heat load by control of evaporate temperatures and compressor suction pressure.
Electric conduction tests at low-temp/low-humid region are available.
Defrosting function
Cyclical defrosting function by setting the operation time
- When the temperature in the chamber is
less than 5℃, heater will warm the inner chamber to required temperature to defrost. - When the temperature in the chamber is
over 5℃, refrigerator will suspend and
defrost.
Humidification delay function
Function to prevent sample from dew condensation at the temperature / humidity rising time, by delaying the humidification start for an optional set time (1 to 120 minutes) after the dry-bulb rise to the required temperature.
USB memory saving function
Saving the trend-graph data to USB memory is available. This is the function which enables USB memory to save the data (measured temperature, measured humidity) shown on the trend-graph of LCD operation panel as CSV file format.
Data log Function
When the operation stops by alarm for abnormal detection, this feature saves the data (the operating situation just before the trouble has occurred) to USB memory. Collecting the data just before the operation-stop enabled user to do trouble analysis.
Operation mode selective function
While operating the program, the user can choose the settings of operation mode by each step. (Choice of Energy saving mode, High load mode) For example electric conduction, a setting
change of the device ability
according to the test pattern is possible.
Unit Control Panel
Color LCD Touch Panel
The color LCD touch panel is adopted so that setting and controlling of the unit will be simple only by touching the displays. The color LCD offers clear view and the system is supported for diverse functions in operation control.
Program name input function
At this function, you may input a program name. Program name can be input by using alphabet, number, and
symbols (!”#%&’()@:,.=+-*/?_) for 14 words (maximum).
Various types of communication interface
By using communication interface, unit is being enabled to external control on operations and measurements from a connected computer or user’s original system unit.
Combined-program operate function
At this function, you may operate 2 or more programs continuously (or by combination). Up to 5 combined programs can be operated at maximum.
Various types of communication interface
By using communication interface, unit is being enabled
to external control on operations and measurements from a connected computer or user’s original system unit.