Standard Series
Test the reliability of your products in different temperatures and humidity. The Constant Temperature & Humidity Chamber allows you to keep the desired temperature and humidity at all times without any effort, saving you time and energy. Constant temperature and humidity chambers simulate the real-world thermal conditions of a product in use. It is especially suited for testing of devices with electric or electronic components, and the materials that come into contact with them. The Standard Series chambers can maintain temperatures from – 70°C to 150°C and relative humidities from 0% to 98% RH depending on the model.
Low power consumption
Efficiently built chambers that make the most of every watt.
High Performance
Best in class performance with commendable efficiency.
Low Noise
Quiet operation ensures a tranquil surrounding.
Compact Size
Built for mobility & space conservancy, our chambers are compact.
Newly designed appearance
Stainless steel (SUS430) was adopted for the exterior material and renewed the design by putting a clear cover in the center of device.
Full functioned scroll compressor loaded
Our scroll compressor, proven for highly efficient performance, is installed to all the models.
Addition of new functions
- Frost-free function
Humidification delay function - USB memory saving function
- Data log function
- Operation mode selective function
(for each program)
Digital over-heat prevention thermostat
Digital over-heat prevention thermostat was adopted as a replacement for the conventional dial over-heat prevention thermostat and
improved the setting operation and temperature control system.
Enlargement of observation window
The capacity of 800L,1000L models expanded the windows size to 316mm×285mm (length×width) from usual size of 270mm×190mm (length×width) with expansion rate of 175%.
Remote Control Operation
Operation from around the world with remote access interfacing. Allows connecting up to 15 chambers from one PC.
Defrosting function
Cyclical defrosting function by setting the operation time
- When the temperature in the chamber is
less than 5℃, heater will warm the inner chamber to required temperature to defrost. - When the temperature in the chamber is
over 5℃, refrigerator will suspend and
defrost.
Humidification delay function
Function to prevent sample from dew condensation at the temperature / humidity rising time, by delaying the humidification start for an optional set time (1 to 120 minutes) after the dry-bulb rise to the required temperature.
USB memory saving function
Saving the trend-graph data to USB memory is available. This is the function which enables USB memory to save the data (measured temperature, measured humidity) shown on the trend-graph of LCD operation panel as CSV file format.
Data log Function
When the operation stops by alarm for abnormal detection, this feature saves the data (the operating situation just before the trouble has occurred) to USB memory. Collecting the data just before the operation-stop enabled user to do trouble analysis.
Operation mode selective function
While operating the program, the user can choose the settings of operation mode by each step. (Choice of Energy saving mode, High load mode) For example electric conduction, a setting
change of the device ability
according to the test pattern is possible.
Unit Control Panel
Color LCD Touch Panel
The color LCD touch panel is adopted so that setting and controlling of the unit will be simple only by touching the displays. The color LCD offers clear view and the system is supported for diverse functions in operation control.
Program name input function
At this function, you may input a program name. Program name can be input by using alphabet, number, and
symbols (!”#%&’()@:,.=+-*/?_) for 14 words (maximum).
Various types of communication interface
By using communication interface, unit is being enabled to external control on operations and measurements from a connected computer or user’s original system unit.
Combined-program operate function
At this function, you may operate 2 or more programs continuously (or by combination). Up to 5 combined programs can be operated at maximum.
Various types of communication interface
By using communication interface, unit is being enabled
to external control on operations and measurements from a connected computer or user’s original system unit.